UTP CAT5e Cable, 305 Meters, PoE, Copper Conductor, PVC Outer Sheath, Flame Retardancy Class CE CPR eca Certified
PFM920I-5EUN
€137.97
€320.86 -57%LO HAI TROVATO A MENO?
Scrivici dove e ti sconteremo la differenza fino a fine mese!
UTP CAT5e CABLE 305 METERS - DAHUA
Quality product
Product details
- UTP cable - Dahua
- 305 Meters
- Copper conductor
- Diameter: 0.45mm ± 0.01mm
- Product excluded from warranty
Data sheet
Model | PFM920I-5EUN |
Conductor | |
Material | Oxygen free copper (99.97% purity) |
Diameter | 0.45mm ± 0.01mm |
Insulation | |
Material | HDPE |
Min. Average Thickness | 0.18mm |
Diameter | 0.81mm±0.1mm |
Color (4 Pairs) | Blue, white/blue; orange, white/orange; green, white/green; brown, white/brown |
Insulation | |
Material | Polyester |
Specification | 500D |
Sheath | |
Material | PVC |
Min. Average Thickness | 0.5mm |
Diameter | 4.7mm ± 0.3mm |
Color | White |
Electrical | |
Max. DC Resistance of a Single Conductor | 12Ω/100m |
Min. Insulation Resistance | 5000MΩ·km |
Max. DC Resistance Unbalance | 2% (intra pairs), 4% (inter pairs) |
Dielectric Strength | No breakdown with 1KV DC for 1 min |
Transmission | |
Characteristic Impedance | 100±15Ω |
Near End Cross Talk | ≥35.30 dB/100 m@100 MHz |
Max. Attenuation | 24.2 dB/100 m@100 MHz |
Return Loss | ≥20.1 dB/100 m@100 MHz |
Mechanical | |
Tensile Strength | Sheath≥13.5 MPa, insulation≥16 MPa |
Elongation at Break | Sheath≥150%, insulation≥300% |
Installation Bending Radius | >8 times of outer cable diameter |
Conductor Elongation at Break | ≥10% |
Environmental | |
Shrinkage of Insulation | ≤5% |
Color Migration Resistance of Insulation | No migration |
Sheath Tensile Strength and Elongation at Break after Aging | ≥12.5 MPa, ≥100% |
Low Temperature Bending Test | No cracking after the test |
Heat Shock Test | No cracking after the test |
Operating Temperature | –20°C to +60°C (–4°F to 140°F) |
Installation Temperature | 0°C to +50°C (32°F to 122°F) |
Storage Temperature and Humidity | –10°C to +40°C (14°F to 104°F), <60% (RH) |
Security | |
Vertical Fire Propagation Test | Comply with IEC 60332-1-2 |
Packaging | |
Cable Length | 305.0 m (1000.66 ft) ± 1.5 m (4.92 ft) |
Packaging Method | 364.0 mm × 364.0 mm × 216.0 mm (14.33" × 14.33" × 8.50") (L × W × H) |
Net Weight | ≥7.0 kg (15.43 lb) |
Gross Weight | ≥8.0 kg (17.64 lb) |
Compliance | |
Executive Standards | Q/DXJ 067-2019, EN50575-2014 |
Certification | CPR Echo |
Further details
Components which by their nature or due to normal wear, tear or decay, require periodic maintenance or replacement (e.g. power supplies, cables, connectors, structural components or anything that is subject to mechanical and electrical stress) are specifically excluded from the Warranty. |
Downloads
Questions (0)
No customer questions for the moment.