UTP CAT5e CABLE 305 METERS - DAHUA
Quality product
Product details
- UTP cable - Dahua
- 305 Meters
- Copper conductor
- Diameter: 0.45mm ± 0.01mm
- Product excluded from warranty
Data sheet
Model | PFM920I-5EUN |
Conductor | |
Material | Oxygen free copper (99.97% purity) |
Diameter | 0.45mm ± 0.01mm |
Insulation | |
Material | HDPE |
Min. Average Thickness | 0.18mm |
Diameter | 0.81mm±0.1mm |
Color (4 Pairs) | Blue, white/blue; orange, white/orange; green, white/green; brown, white/brown |
Insulation | |
Material | Polyester |
Specification | 500D |
Sheath | |
Material | PVC |
Min. Average Thickness | 0.5mm |
Diameter | 4.7mm ± 0.3mm |
Color | White |
Electrical | |
Max. DC Resistance of a Single Conductor | 12Ω/100m |
Min. Insulation Resistance | 5000MΩ·km |
Max. DC Resistance Unbalance | 2% (intra pairs), 4% (inter pairs) |
Dielectric Strength | No breakdown with 1KV DC for 1 min |
Transmission | |
Characteristic Impedance | 100±15Ω |
Near End Cross Talk | ≥35.30 dB/100 m@100 MHz |
Max. Attenuation | 24.2 dB/100 m@100 MHz |
Return Loss | ≥20.1 dB/100 m@100 MHz |
Mechanical | |
Tensile Strength | Sheath≥13.5 MPa, insulation≥16 MPa |
Elongation at Break | Sheath≥150%, insulation≥300% |
Installation Bending Radius | >8 times of outer cable diameter |
Conductor Elongation at Break | ≥10% |
Environmental | |
Shrinkage of Insulation | ≤5% |
Color Migration Resistance of Insulation | No migration |
Sheath Tensile Strength and Elongation at Break after Aging | ≥12.5 MPa, ≥100% |
Low Temperature Bending Test | No cracking after the test |
Heat Shock Test | No cracking after the test |
Operating Temperature | –20°C to +60°C (–4°F to 140°F) |
Installation Temperature | 0°C to +50°C (32°F to 122°F) |
Storage Temperature and Humidity | –10°C to +40°C (14°F to 104°F), <60% (RH) |
Security | |
Vertical Fire Propagation Test | Comply with IEC 60332-1-2 |
Packaging | |
Cable Length | 305.0 m (1000.66 ft) ± 1.5 m (4.92 ft) |
Packaging Method | 364.0 mm × 364.0 mm × 216.0 mm (14.33" × 14.33" × 8.50") (L × W × H) |
Net Weight | ≥7.0 kg (15.43 lb) |
Gross Weight | ≥8.0 kg (17.64 lb) |
Compliance | |
Executive Standards | Q/DXJ 067-2019, EN50575-2014 |
Certification | CPR Echo |